Rapid Test Oral Fluid Device

The easiest-to-use instant testing product on the market. 

A collection cup and testing device that delivers: instant results, unrivalled ease, convenience, and accuracy. 

This self-contained Saliva screening device detects the presence of parent drug  in minutes, using  AS4760 cut-off levels.

 

Tests are available in configurations of four to 15 of the following drugs and/or adulterants.

We’re different

What distinguishes Rapid Test® from other instant products is its superior ease of use.

  • No handling or manipulation to activate testing
  • No tipping or tilting cup to activate test
  • No dipping reagent strips or test cards into specimen
  • No dripping specimen with pipettes

PRODUCT

AM-O-264-A

Drug Screen 
Configuration: 
Cylindrical Cup

Amphetamines, Benzodiazepines, Cocaine, Methamphetamines Opiates,

THC 

OXY

Packaging

Expiry

20/ box
4 boxes / ctn

>12mths

Australian Standards AS4760/2019 Saliva Drug Test 

【DIRECTIONS FOR USE】

Allow the test Cup, specimen, and/or controls to reach room temperature (15-30°C) prior to testing. Instruct the donor to not place anything in the mouth including food, drink, gum ortobacco products for at least 10 minutes prior to collection.

1. Remove the collector from the sealed pouch and collect oral fluid specimen as follows:

Important: Place the tongue against the upper and lower jaws and roots to enrich the oral fluid before oral fluid collection.

Insert the sponge end into the mouth, actively swab around the gums on both sides of the mouth and under the tongue and chew the sponge tenderly, place the sponge end under the tongue for a total of 2-3 minutes until the sponge becomes fully saturated.

Gently pressing the sponge between the tongue and teeth will assist saturation. No hard spots should be felt on the sponge when saturated.

2. Remove the collector from the mouth. Place saturated oral fluid collector into test cup and screw the collector to press sponge fully to release oral fluid. Place the test cup on a clean and level surface. Remove the peel off label, wait for the flow to appear in test windows and start a timer.

If the sample does not migrate in the test cup even after 3 minutes, please rotate the cup 4-5 times.

3. Read the test results at 3-10 minutes.

If all lines are clearly visible at 3 minutes or sooner, then the test can be interpreted as negative and discarded. If any lines are not visible at 3 minutes, then the test should be re-read at 10 minutes.

4. For Alcohol strip, when applicable, the results should be read at 2 minutes. Compare the color of the reaction pad with the chart provided separately/on foil pouch to determine the relative oral fluid alcohol level.

Australian Standards AS4760 Saliva Drug Test  

PRODUCT

AM-O-264

Drug Screen 
Configuration: 
Cylindrical Cup

Packaging

Amphetamines, Benzodiazepines, Cocaine, Methamphetamines Opiates,

THC 

Cannabis

25 / box
4 boxes / ctn

Expiry

>12mths

Presumptive Positive: 

One colour line only is visible in each controlzone. No colour line whatsoever appearsin the appropriate test zone, indicatinga presumptive positive result for thecorresponding drug of that specific zone.

 

 

Negative: 

Two colored lines are visible in thecontrol zone and in the appropriate test zone,indicating that concentration of the drug is below the detection limit of the test or not present.